| This
FR tape conforms to the U.S. Federal Aviation Administration
specification FAR25.853 (b). It can reach the premium
high strength with high cycle life. For automobile and
aviation industries, other special fire retardant products.
Vertical Test
Material to be tested:
The burner flame shall
be applied vertically
at the middle of the
lower edge of the specimen shall be min. of 70mm x 307
mm.
(1) Combined (after) flame and glowing time: Average
of the combined time shall not
exceed 15 sec. From the removal of the test flame.
(2) Flame time of drippings.
Drippings shall not continue to flame for more than
an
average of 5 sec.
(3) Burner length of
the specimen
The Average burn length
shall not exceed 200mm.
|